Clapm Meters


Fluke rugged. Fluke reliable. Fluke precise.
True-rms measurements and optimized ergonomics make the 320 Series Clamp Meters the best general troubleshooting tools for commercial and residential electricians. The Fluke 323 model is ideally suited for current measurements up to 400 A in tight cable compartments
Measurement capability

  • 400 A ac current measurement
  • 600 V ac and dc voltage measurement
  • True-rms ac voltage and current for accurate measurements on non-linear signals
  • Resistance measurement up to 4 kΩ with continuity detection


Features

  • Slim, ergonomic design
  • CAT IV 300V/CAT III 600 V safety rating
  • Hold button
  • Two-year warranty
  • Soft carrying case

323 324 325
AC current Range 400.0 A 40.00 A/400.0 A 40.00 A/400.0 A
Accuracy 2 % ± 5 digits
(45 Hz to 65 Hz)
2.5 % ± 5 digits
(65 Hz to 400 Hz)
1.5 % ± 5 digits
(45 Hz to 400 Hz)
Note: Add 2 % for
position sensitivity
2 % ± 5 digits
(45 Hz to 65 Hz)
2.5 % ± 5 digits
(65 Hz to 400 Hz)
DC current Range 40.00 A/400.0 A
Accuracy 2 % ± 5 digits
AC voltage Range 600.0 V 600.0 V 600.0 V
Accuracy 1.5 % ± 5 digits 1.5 % ± 5 digits 1.5 % ± 5 digits
DC voltage Range 600.0 V 600.0 V 600.0 V
Accuracy 1.0 % ± 5 digits 1.0 % ± 5 digits 1.0 % ± 5 digits
Resistance Range 400.0 Ω/ 4000 Ω 400.0 Ω/ 4000 Ω 400.0 Ω/ 4000 Ω/ 40.00 kΩ
Accuracy 1.0 % ± 5 digits 1.0 % ± 5 digits 1.0 % ± 5 digits
Continuity ≤ 70 Ω ≤ 30 Ω ≤ 30 Ω
Capacitance 0 to 100.0 μF
100 μF to 1000 μF
0 to 100.0 μF
100 μF to 1000 μF
Frequency 5.0 Hz to 500.0 Hz
AC response True-rms True-rms True-rms
Backlight Yes Yes
Data hold Yes Yes Yes
Contact temperature -10.0 °C to 400.0 °C
(14.0 °F to 752.0 °F)
-10.0 °C to 400.0 °C
(14.0 °F to 752.0 °F)
Min/Max Yes
Size H x W x D (mm) 207 x 75 x 34 207 x 75 x 34 207 x 75 x 34
Max wire diameter 30 mm (600 MCM) 30 mm (600 MCM) 30 mm (600 MCM)
Weight 265 g 208 g 283 g
Category rating CAT III 600 V
CAT IV 300 V
CAT III 600 V
CAT IV 300 V
CAT III 600 V
CAT IV 300 V
Warranty Two-year Two-year Two-year

Fluke rugged. Fluke reliable. Fluke precise.
True-rms measurements and optimized ergonomics make the 320 Series Clamp Meters the best general troubleshooting tools for commercial and residential electricians. The 323, 324 and 325 are designed to verify the presence of load current, AC voltage and continuity of circuits, switches, fuses and contacts. These small and rugged clamp meters are ideally suited for current measurements up to 400 A in tight cable compartments. The Fluke 324 model also includes temperature and capacitance measurement capabilities.

Measurement capability

  • 400 A ac current measurement
  • 600 V ac and dc voltage measurement
  • True-rms ac voltage and current for accurate measurements on non-linear signals
  • Resistance measurement up to 4 kΩ with continuity detection
  • Temperature and capacitance measurement


Features

  • Slim, ergonomic design
  • Large, easy to read backlight display
  • CAT IV 300V/CAT III 600 V safety rating
  • Hold button
  • Two-year warranty
  • Soft carrying case

323 324 325
AC current Range 400.0 A 40.00 A/400.0 A 40.00 A/400.0 A
Accuracy 2 % ± 5 digits
(45 Hz to 65 Hz)
2.5 % ± 5 digits
(65 Hz to 400 Hz)
1.5 % ± 5 digits
(45 Hz to 400 Hz)
Note: Add 2 % for
position sensitivity
2 % ± 5 digits
(45 Hz to 65 Hz)
2.5 % ± 5 digits
(65 Hz to 400 Hz)
DC current Range 40.00 A/400.0 A
Accuracy 2 % ± 5 digits
AC voltage Range 600.0 V 600.0 V 600.0 V
Accuracy 1.5 % ± 5 digits 1.5 % ± 5 digits 1.5 % ± 5 digits
DC voltage Range 600.0 V 600.0 V 600.0 V
Accuracy 1.0 % ± 5 digits 1.0 % ± 5 digits 1.0 % ± 5 digits
Resistance Range 400.0 Ω/ 4000 Ω 400.0 Ω/ 4000 Ω 400.0 Ω/ 4000 Ω/ 40.00 kΩ
Accuracy 1.0 % ± 5 digits 1.0 % ± 5 digits 1.0 % ± 5 digits
Continuity ≤ 70 Ω ≤ 30 Ω ≤ 30 Ω
Capacitance 0 to 100.0 μF / 100 μF to 1000 μF 0 to 100.0 μF / 100 μF to 1000 μF
Frequency 5.0 Hz to 500.0 Hz
AC response True-rms True-rms True-rms
Backlight Yes Yes
Data hold Yes Yes Yes
Contact temperature -10.0 °C to 400.0 °C
(14.0 °F to 752.0 °F)
-10.0 °C to 400.0 °C
(14.0 °F to 752.0 °F)
Min/Max Yes
Size H x W x D (mm) 207 x 75 x 34 207 x 75 x 34 207 x 75 x 34
Max wire diameter 30 mm (600 MCM) 30 mm (600 MCM) 30 mm (600 MCM)
Weight 265 g 208 g 283 g
Category rating CAT III 600 V
CAT IV 300 V
CAT III 600 V
CAT IV 300 V
CAT III 600 V
CAT IV 300 V
Warranty Two-year Two-year Two-year

Fluke rugged. Fluke reliable. Fluke precise.

True-rms measurements and optimized ergonomics make the 320 Series Clamp Meters the best general troubleshooting tools for commercial and residential electricians. The 323, 324 and 325 are designed to verify the presence of load current, AC voltage and continuity of circuits, switches, fuses and contacts. These small and rugged clamp meters are ideally suited for current measurements up to 400 A in tight cable compartments. The Fluke 325 also offers DC current and frequency measurements.

Measurement capability

  • 400 A ac and dc current measurement
  • 600 V ac and dc voltage measurement
  • True-rms ac voltage and current for accurate measurements on non-linear signals
  • Resistance measurement up to 40 kΩ with continuity detection
  • Temperature and capacitance measurement
  • Frequency measurement


Features

  • Slim, ergonomic design
  • Large, easy to read backlight display
  • CAT IV 300V/CAT III 600 V safety rating
  • Hold button
  • Two-year warranty
  • Soft carrying case

323 324 325
AC current Range 400.0 A 40.00 A/400.0 A 40.00 A/400.0 A
Accuracy 2 % ± 5 digits
(45 Hz to 65 Hz)
2.5 % ± 5 digits
(65 Hz to 400 Hz)
1.5 % ± 5 digits
(45 Hz to 400 Hz)
Note: Add 2 % for
position sensitivity
2 % ± 5 digits
(45 Hz to 65 Hz)
2.5 % ± 5 digits
(65 Hz to 400 Hz)
DC current Range 40.00 A/400.0 A
Accuracy 2 % ± 5 digits
AC voltage Range 600.0 V 600.0 V 600.0 V
Accuracy 1.5 % ± 5 digits 1.5 % ± 5 digits 1.5 % ± 5 digits
DC voltage Range 600.0 V 600.0 V 600.0 V
Accuracy 1.0 % ± 5 digits 1.0 % ± 5 digits 1.0 % ± 5 digits
Resistance Range 400.0 Ω/ 4000 Ω 400.0 Ω/ 4000 Ω 400.0 Ω/ 4000 Ω/ 40.00 kΩ
Accuracy 1.0 % ± 5 digits 1.0 % ± 5 digits 1.0 % ± 5 digits
Continuity ≤ 70 Ω ≤ 30 Ω ≤ 30 Ω
Capacitance 0 to 100.0 μF / 100 μF to 1000 μF 0 to 100.0 μF / 100 μF to 1000 μF
Frequency 5.0 Hz to 500.0 Hz
AC response True-rms True-rms True-rms
Backlight Yes Yes
Data hold Yes Yes Yes
Contact temperature -10.0 °C to 400.0 °C
(14.0 °F to 752.0 °F)
-10.0 °C to 400.0 °C
(14.0 °F to 752.0 °F)
Min/Max Yes
Size H x W x D (mm) 207 x 75 x 34 207 x 75 x 34 207 x 75 x 34
Max wire diameter 30 mm (600 MCM) 30 mm (600 MCM) 30 mm (600 MCM)
Weight 265 g 208 g 283 g
Category rating CAT III 600 V
CAT IV 300 V
CAT III 600 V
CAT IV 300 V
CAT III 600 V
CAT IV 300 V
Warranty Two-year Two-year Two-year

Big features, small package

The Fluke 321 and 322 are designed to verify the presence of load current, AC voltage and continuity of circuits, switches, fuses and contacts. These small and rugged clamp meters are ideally suited for current measurements up to 400 A in tight cable compartments. The Fluke 322 also offers DC voltage measurements and has a higher resolution for loads below 40 A.

These affordable instruments combine a compact package with a strong feature set:

  • New smaller size fits easily into tight places
  • Precise measurements with 1.8% basic accuracy
  • Resolution up to 0.01A and 0.1 V
  • Measures AC current to 400 A
  • Measures AC volts to 600 V
  • Measures DC volts to 600 V (Fluke 322 only)
  • Resistance measurement to 400 Ω
  • Continuity for quick checking of shorts
  • Automatic low battery indicator
  • Display hold function
  • Two year warranty

Voltage DC
Range:  0 – 400 V (Fluke 322 only)
Resolution:  0.1 V
Range:  0 – 600 V (Fluke 322 only)
Resolution:  1 V
Accuracy:  1% ± 5 counts
Voltage AC
Range:  0 – 400 V
Resolution:  0.1 V
Range:  0 – 600 V
Resolution:  1 V
Accuracy:  1.2% ± 5 counts (50 – 400 Hz)
AC Response:  Averaging
Current AC
Range:  0 – 400 A
Resolution:  0.1 A
Range:  0 – 40 A (Fluke 322 only)
Resolution:  0.01 A
Accuracy:  1.8% ± 5 counts (50 – 60 Hz)
Accuracy:  3.0% ± 5 counts (60 – 400 Hz)
AC Response:  Averaging
Resistance
Range:  0 – 400 Ω
Resolution:  0.1 Ω
Accuracy:  1% ± 5 counts
Continuity
 <= 30 Ω
Environmental Specifications
Operating Temperature
 -10°C to +50°C
Storage Temperature
 -30 ºC to +60 ºC
Operating Altitude
 2,000 meters
Temperature De-rating
 Add 0.1 x specified accuracy for each ºC above 28ºC or below 18ºC
Safety Specifications
Safety Rating
 IEC 1010-2-032, 600V CAT III
Mechanical & General Specifications
Size
 190 x 63 x 35 mm
Weight
 230 g
Warranty
 Two years
Battery Life
 100 hours typical (2 AAA carbon zinc)
Jaw Opening
 25 mm

Be ready for anything.

The new Fluke 373 Clamp Meter offers improved performance perfect for any ac only current measurement situations. Featuring true-rms ac voltage and current measurements, and resistance measurement up to 6000Ω with continuity detection, the Fluke 373 is everything you need, plus a little more.

Features and benefits

  • 600 A ac current measurement with fixed jaw
  • 600 V ac and dc voltage measurement
  • State of the art signal processing allows for use in noisy electrical environments while providing stable readings
  • CAT IV 300 V, CAT III 600 V
  • True-rms ac voltage and current for accurate measurements on non-linear signals
  • Large, easy to read backlight display automatically sets the correct measurement range so you do not need to change the switch positions while taking a measurement
  • Three-year warranty
  • Soft carrying case

AC Current
Range 600.0 A
Resolution 0.1 A
Accuracy 2 % ± 5 digits (48 – 62 Hz)
Crest Factor (50/60 Hz) 2.5 @ 600 A
AC Voltage
Range 600.0 V
Resolution 0.1 V
Accuracy 1.0 % ± 5 digits (48 – 62 Hz)
DC Voltage
Range 600.0 V
Resolution 0.1 V
Accuracy 1 % ± 5 digits
Resistance
Range 600.0 Ω/6000 Ω
Resolution 0.1 Ω/1 Ω
Accuracy 1 % ± 5 digits
Continuity Beeper 30 Ω
Capacitance
Range 10.0 – 100.0 μF / 1000 μF
Resolution 0.1 μF/1 μF
Accuracy 1.9 % ± 2 digits
Mechanical Specifications
Size (L x W x H) 232 mm x 85 mm x 45 mm
Weight 370 g
Environmental Specifications
Operating Temperature -10 °C to +50 °C
Storage Temp -40 °C to +60 °C
Operating Humidity Non condensing (< 10 °C)
≤ 90 % RH (at 10 °C to 30 °C)
≤ 75 % RH (at 30 °C to 40 °C)
≤ 45 % RH (at 40 °C to 50 °C)
(Without Condensation)
Operating Altitude 3000 meters
Storage Altitude 12,000 meters
EMI, EMC Meets all applicable requirements in EN61326-1:2006
Temperature Coefficients Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C
Safety Compliance ANSI/ISA S82.02.01:2004
CAN/CSA-C22.2 No. 61010-1-04
IEC/EN 61010-1:2001, 600V CAT III, 300V CAT IV
Pollution Degree 2
EN/IEC 61010-2-32:2002
EN/IEC 61010-031:2002/A1:2008
cert agency logo
Agency Approvals cert agency logo
Batteries 2 AA, NEDA 15A, IEC LR6

Be ready for anything

The Fluke 374 True-rms Clamp Meter can read up to 600 V and 600 A in both ac and dc modes. Additionally, the 374 is compatible with the new iFlex flexible current probe (sold separately), which increases the measurement range to 2500 A ac and provides increased display flexibility, and improved wire access.

Features and benefits

  • iFlex flexible current probe (sold separately) expands the measurement range to 2500 A ac while providing increased display flexibility, ability to measure awkward sized conductors and improved wire access
  • CAT IV 600 V, CAT III 1000 V
  • Propietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
  • Ergonomic design fits in your hand and can be used while wearing personal protective equipment
  • Large, easy to read backlight display automatically sets the correct measurement range so you do not need to change the switch positions while taking a measurement
  • Three-year warranty
  • Soft carrying case

AC Current via Jaw
Range 600.0 A
Resolution 0.1 A
Accuracy 2% ± 5 digits (10-100 Hz)
2.5% ± 5 digits (100-500 Hz)
Crest Factor (50/60 Hz) 3 @ 500 A (375 and 376 only)
2.5 @ 600 A
1.42 @1000 A (376 only)
Add 2% for C.F. > 2
AC Current via Flexible Current Probe
Range 2500 A
Resolution 0.1 A (≤ 600 A)
1 A (≤ 2500 A)
Accuracy 3% ±5 digits (5 – 500 Hz)
Crest Factor (50/60Hz) 3.0 at 1100 A (375 and 376 only)
2.5 at 1400 A
1.42 at 2500 A
Add 2% for C.F. > 2
Distance from Optimum i2500-10 Flex i2500-18 Flex Error
Flexible current probe A 0.5 in (12.7 mm) 1.4 in (35.6 mm) ± 0.5%
B 0.8 in (20.3 mm) 2.0 in (50.8 mm) ± 1.0%
C 1.4 in (35.6 mm) 2.5 in (63.5 mm) ± 2.0%
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
DC Current
Range 600.0 A
Resolution 0.1 A
Accuracy 2% ± 5 digits
AC Voltage
Range 600.0 V
Resolution 0.1 V
Accuracy 1.5% ± 5 digits (20 – 500 Hz)
DC Voltage
Range 600.0 V
Resolution 0.1 V
Accuracy 1% ± 5 digits
Capacitance
Range 1000 μF
Resolution 0.1 μF (≤ 100 μF)
1 μ F (≤ 1000 μF)
Accuracy 1% ± 4 digits
Mechanical Specifications
Size (L x W x H) 246 mm x 83 m x 43 mm
Weight 388 g
Jaw Opening 34 mm
Flexible Current Probe Diameter 7.5 mm
Flexible Current Probe Cable Length
(head to electronics connector)
1.8 m
Environmental Specifications
Operating Temperature 10°C – +50°C
Storage Temp -40°C – +60°C
Operating Humidity Non condensing (< 10 –°C)
≤ 90% RH (at 10°C – 30°C)
≤ 75% RH (at 30°C – 40°C)
≤ 45% RH (at 40°C – 50°C)
Operating Altitude 3000 meters
Storage Altitude 12,000 meters
EMC EN 61326-1:2006
Temperature Coefficients Add 0.1 x specified accuracy for each
degree C above 28°C or below 18°C
Safety Specifications
Safety Compliance CAN/CSA-C22.2 No. 61010-1-04
ANSI/UL 61010-1:2004
ANSI/ISA-61010-1 (82.02.01):2004
EN/IEC 61010-1:2001 to
1000V Measurement Category (CAT) III
600V Measurement Category (CAT) IV
Pollution Degree 2
EN/IEC 61010-2-032:2002
EN/IEC 61010-031:2002+A1:2008
Agency Approvals
Batteries 2 AA, NEDA 15A, IEC LR6

Need more hours in your day?

Save time by NOT breaking the loop on 4-20 mA signal measurements.

Are you spending time:

  • Taking mA measurements by removing a wire and breaking the loop
  • Calling the control room to isolate a loop
  • Testing analog input/output on a console
  • Troubleshooting devices with mA inputs and outputs
  • Repairing intermittent or erratic 4-20 mA loops
  • Going back to the shop to get extra tools

If you need more time in your busy day take a good look at the Fluke 771 mA Clamp Meters. It’s designed to save you time, and money, by eliminating time wasting activities. Now you can troubleshoot and repair 4-20 mA loops without breaking the loop or bringing down the system.

The 771 mA Clamp Meter features:

  • Best in class 0.2 % accuracy
  • 0.01 mA resolution and sensitivity
  • Measure 4 to 20 mA signals without ”breaking the loop”
  • Measure mA signals for PLC and control system analog I/O
  • Dual backlit display with both mA measurement and percent of 4 to 20 mA span
  • Measurement Spotlight illuminates hard to see wires in dark enclosures
  • Detachable clamp with extension cable for measurements in tight locations
  • Measure 10 to 50 mA signals in older control systems using the 99.9 mA range
  • Automatically change the 4 to 20 mA output for remote testing
  • Power saving features, auto-off, backlight timeout extend battery life
  • Hold function captures and displays changing measurements

Diameter of measurable conductor 0.177” or 4.5 mm max
Operating temperature -10 to 50 ºC
Storage Temperature -25 to 60ºC
Operating Humidity < 90% @ <30 ºC, < 75% @ 30 to 55ºC
Operating Altitude 0 to 2000 m
IP Rating IP 40
Size 59 x 38 x 212 mm, (2.32 x 1.5 x 8.35 in.)
Weight 260G, (9.1 oz.)
Vibration Random 2 g, 5 to 500 Hz
Shock 1 meter drop test (except the jaw)
EMI/RFI Meets EN61326-1
Note: For current measurement w/ JAW, add 1mA to specification for EMC field strengths of 1V/m up to 3V/m.
Temperature Coefficient 0.01% ºC
(<18? or > 28?)
Power, battery life (2) AA 1.5 V Alkaline, IEC LR6, 40 hours typical
Warranty Three years for electronics
one year for cable and clamp assembly
mA measurement (Measured by clamp) Resolution and Range:      0 to 20.99 mA
Accuracy:                         0.2% +2 counts
Resolution and Range:      21.0 mA to 100.0 mA
Accuracy:                         1% + 5 counts

Need more hours in your day?

Save time by NOT breaking the loop on 4-20 mA signal measurements.

Are you spending time:

  • Taking mA measurements by removing a wire and breaking the loop
  • Calling the control room to isolate a loop
  • Testing analog input/output on a console
  • Troubleshooting devices with mA inputs and outputs
  • Repairing intermittent or erratic 4-20 mA loops
  • Going back to the shop to get extra tools

If you need more time in your busy day take a good look at the Fluke 773 mA Clamp Meters. It’s designed to save you time, and money, by eliminating time wasting activities. Now you can troubleshoot and repair 4-20 mA loops without breaking the loop or bringing down the system.

The 773 mA Clamp Meter features:

  • Best in class 0.2 % accuracy
  • 0.01 mA resolution and sensitivity
  • Measure 4 to 20 mA signals without ”breaking the loop”
  • Measure mA signals for PLC and control system analog I/O
  • Dual backlit display with both mA measurement and percent of 4 to 20 mA span
  • Measurement Spotlight illuminates hard to see wires in dark enclosures
  • Detachable clamp with extension cable for measurements in tight locations
  • Measure 10 to 50 mA signals in older control systems using the 99.9 mA range
  • Automatically change the 4 to 20 mA output for remote testing
  • Power saving features, auto-off, backlight timeout extend battery life
  • Hold function captures and displays changing measurements
  • Measure 4 to 20 mA signals with in-circuit measurement
  • Simultaneous mA in-circuit measurement with 24V loop power for powering and testing transmitters
  • Source 4 to 20 mA signals for testing control system I/O or I/Ps
  • mA output linear ramp or 25% step output
  • Automatically change the 4 to 20 mA output for remote testing
  • DC voltage measurement to verify 24V power supplies or voltage I/O signals
  • Source DC voltage to test input devices that accept a 1-5V or 0 to 10V signals
  • Scaled mA output provides a continuous mA signal that corresponds to the 4 to 20 mA signal measured by the mA clamp
  • Enables milliamp signal logging to a separate logging device without breaking the loop
  • Output mA signal enables a logging DMM or other device to record the 4- to 20 mA signal without breaking the loop
  • mA in/out: simultaneously measure the mA signal with the clamp and source a mA signal
  • Apply a mA input signal to a device and measure its’ 4-20 mA output on devices such as valves or mA isolators
  • Voltage output linear ramp or 25% step output
  • Automatically change the voltage output for remote testing

Diameter of measurable conductor 0.177 or 4.5 mm max
Operating temperature -10 to 50 ºC
Storage Temperature -25 to 60ºC
Operating Humidity < 90% @ <30 ºC, < 75% @ 30 to 55ºC
Operating Altitude 0 to 2000 m
IP Rating IP 40
Size 44 x 70 x 246 mm (2 7/8 x 5 ¾ x 11 5/8 in)
Weight 410 g, (14.4 oz)
Vibration Random 2 g, 5 to 500 Hz
Shock 1 meter drop test (except the jaw)
EMI/RFI Meets EN61326-1
Note: For current measurement w/ JAW, add 1mA to
specification for EMC field strengths of 1V/m up to 3V/m.
Temperature Coefficient 0.01% ºC
(<18ºC or > 28ºC)
Power, battery life (4) AA 1.5 V Alkaline, IEC LR6, 12 hours in mA source into 500 ohms
Warranty Three years for electronics
one year for cable and clamp assembly

 

Functional Specifications

mA measurement
(Measured by clamp) 771/772/773
Resolution and Range:          0 to 20.99 mA
Accuracy:                             0.2%+5 counts
Resolution and Range:          21.0 mA to 100.0 mA
Accuracy:                             1% + 5 counts
mA measurement
(Measured in series with test jacks) 772/773
Resolution and Range:          0 to 24.00 mA
Accuracy:                             0.2% + 2counts
mA source (Maximum mA Drive:
24 mA into 1,000 ohms)
Resolution and Range:          0 to 24.00 mA
Accuracy:                             0.2% + 2counts
mA simulate
(Maximum voltage 50 V dc)
Resolution and Range:          0 to 24.00 mA
Accuracy:                             0.2% + 2counts
Voltage source (2 mA maximum drive current) Resolution and Range:          0 to 10.00 V dc
Accuracy:                             0.2% + 2counts
Voltatge Mesaure Resolution and Range:          0 to 30.00 V dc
Accuracy:                             0.2% + 2counts

This kit is a direct replacement for the obsolete 116/322 HVAC combo kit.

For the complete solution to HVAC troubleshooting the extra value-packed HVAC Multimeter and Clamp Meter Combo Kit, provides the ability to troubleshoot and solve problems more efficiently by providing all the needed accessories an HVAC professional would need in a compact carry case.

Fluke116 Digital Multimeter. Designed by Electricians. Engineered by Fluke.

  • Fluke 116 HVAC Multimeter with Temperature and Microamps.
  • TL175 Hard Point Test Lead Set.
  • TPak ToolPak Magnetic Meter Hanging Strap.
  • Flexible Cuff Pipe Clamp Thermocouple.
  • 80BK Integrated Temperature Probe.
  • 80AK-A Thermocouple Adapter.
  • C115 Deluxe Soft Carrying Case with Shoulder Strap.

Fluke 323 True-rms Clamp Meter. Rugged. Reliable. Precise.

  • 400 A ac current measurement.
  • 600 V ac and dc voltage measurement.
  • True-rms ac voltage and current for accurate measurements on non-linear signals.
  • Resistance measurement up to 40 kΩ with continuity detection.
  • Slim, ergonomic design.
  • CAT IV 300V/CAT III 600 V safety rating.

Maximum voltage between any terminal and earth ground 600 V
Surge protection 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Display 6,000 counts, updates 4 per second
Bar graph 33 segments, updates 32 per second
Operating Temperature -10 °C to + 50 °C
Storage Temperature -40 °C to + 60 °C
Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life 400 hours typical, without backlight

 

Accuracy Specifications
DC millivolts Range 600.0 mV
Resolution 0.1 mV
Accuracy ± ([% of reading] + [counts]): 0.5% + 2
DC volts Range/Resolution 6.000 V / 0.001 V
Range/Resolution 60.00 V / 0.01 V
Range/Resolution 600.00 V / 0.1 V
Accuracy ± ([% of reading] + [counts]): 0.5% + 2
Auto volts Range 600.0 V
Resolution 0.1 V
Accuracy 2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts1 true-rms Range 600.0 mV
Resolution 0.1 mV
Accuracy 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms Range/Resolution 6.000 V / 0.001 V
Range/Resolution 60.00 V / 0.01 V
Range/Resolution 600.0 V / 0.1 V
Accuracy 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
Continuity Range 600 Ω
Resolution 1 Ω
Accuracy Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer.
Ohms Range/Resolution 600.0 Ω / 0.1 Ω
Range/Resolution 6.000 kΩ / 0.001 kΩ
Range/Resolution 60.00 kΩ / 0.01 kΩ
Range/Resolution 600.0 kΩ / 0.1 kΩ
Range/Resolution 6.000 MΩ / 0.001 MΩ
Accuracy 0.9 % + 1
Range/Resolution 40.00 MΩ / 0.01 MΩ
Accuracy 1.5 % + 2
Diode Test Range/Resolution  2.000 V / 0.001 V
Accuracy  0.9% + 2
Capacitance Range/Resolution 1000 nF / 1 nF
Range/Resolution 10.00 μF / 0.01 μF
Range/Resolution 100.0 μF / 0.1 μF
Range/Resolution 9999 μF / 1 μF
Range/Resolution 100 μF to 1000 μF
Accuracy 1.9% + 2
Range/Resolution > 1000 μF
Accuracy 5% + 20%
LoZ capacitance Range 1 nF to 500 μF
Accuracy 10% + 2 typical
Temperature2 (Type-K thermocouple) Range/Resolution -40 °C to 400 °C / 0.1 °C
Accuracy 1% + 102
Range/Resolution -40 °F to 752 °F / 0.2 °F
Accuracy 1% + 182
AC μamps true-rms (45 Hz to 500 Hz) Range/Resolution 600.0 μA / 0.1 μA
Accuracy 1.0% + 2
DC μamps Range/Resolution 600.0 μA / 0.1 μA
Accuracy 1.0% + 2
Hz (V or A input)2 Range/Resolution 99.99 Hz / 0.01 Hz
Range/Resolution 999.99 Hz / 0.1 Hz
Range/Resolution 9.999 Hz / 0.001 Hz
Range/Resolution 50.00 Hz / 0.01 Hz
Accuracy 0.1% + 2

Be ready for anything.

With true-rms ac voltage and current measurements, the Fluke 375 Clamp Meter can read up to 600 V and 600 A in both ac and dc modes, and is capable of frequency measurement up to 500 Hz. Additionally, the 375 is compatible with the new iFlex flexible current probe (sold separately), which expands the measurement range to 2500 A ac.

Features and benefits

  • iFlex flexible current probe expands the measurement range to 2500 A ac while providing increased display flexibility, ability to measure awkward sized conductors and improved wire access.
  • CAT IV 600 V, CAT III 1000 V
  • True-rms ac voltage and current for accurate measurements on non-linear signals
  • 500 mV dc measurement range to interface with other accessories
  • Integrated low pass filter and state of the art signal processing allows for use in noisy electrical environments while providing stable readings
  • Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
  • Ergonomic design fits in your hand and can be used while wearing protective equipment
  • Large, easy to read backlight display automatically sets the correct measurement range so you do not need to change the switch positions while taking a measurement
  • Three-year warranty
  • Soft carrying case

AC Current via Jaw
Range 600.0 A
Resolution 0.1 A
Accuracy 2% ± 5 digits (10-100 Hz)
2.5% ± 5 digits (100-500 Hz)
Crest Factor (50/60 Hz) 3 @ 500 A
Add 2% for C.F. > 2
AC Current via Flexible Current Probe
Range 2500 A
Resolution 0.1 A (≤ 600 A)
1 A (≤ 2500 A)
Accuracy 3% ±5 digits (5 – 500 Hz)
Crest Factor (50/60Hz) 3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
Add 2% for C.F. > 2
Distance from Optimum i2500-10 Flex i2500-18 Flex Error
Flexible current probe A 0.5 in (12.7 mm) 1.4 in (35.6 mm) ± 0.5%
B 0.8 in (20.3 mm) 2.0 in (50.8 mm) ± 1.0%
C 1.4 in (35.6 mm) 2.5 in (63.5 mm) ± 2.0%
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
DC Current
Range 600.0 A
Resolution 0.1 A
Accuracy 2% ± 5 digits
AC Voltage
Range 600.0 V
Resolution 0.1 V
Accuracy 1.5% ± 5 digits (20 – 500 Hz)
DC Voltage
Range 600.0 V
Resolution 0.1 V
Accuracy 1% ± 5 digits
mV dc
Range 500.0 mV
Resolution 0.1 mV
Accuracy 1% ± 5 digits
Frequency via Jaw
Range 5.0 – 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ± 5 digits
Trigger Level 5 – 10 Hz, ≥10 A
10 – 100 Hz, ≥5 A
100 – 500 Hz, ≥10 A
Frequency via Flexible Current Probe
Range 5.0 – 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ± 5 digits
Trigger Level 5 – 20 Hz, ≥ 25 A
20 – 100 Hz, ≥ 20 A
100 – 500 Hz, ≥ 25 A
Resistance
Range 60 kΩ
Resolution 0.1 Ω (≤ 600 Ω)
1 Ω (≤ 6000 Ω)
10 Ω (≤ 60 kΩ)
Accuracy 1% ± 5 digits
Capacitance
Range 1000 μF
Resolution 0.1 μF (≤ 100 μF)
1 μ F (≤ 1000 μF)
Accuracy 1% ± 4 digits
Mechanical Specifications
Size (L x W x H) 246 mm x 83 m x 43 mm
Weight 388 g
Jaw Opening 34 mm
Flexible Current Probe Diameter 7.5 mm
Flexible Current Probe Cable Length
(head to electronics connector)
1.8 m
Environmental Specifications
Operating Temperature 10°C – +50°C
Storage Temp -40°C – +60°C
Operating Humidity Non condensing (< 10 –°C)
≤ 90% RH (at 10°C – 30°C)
≤ 75% RH (at 30°C – 40°C)
≤ 45% RH (at 40°C – 50°C)
Operating Altitude 3000 meters
Storage Altitude 12,000 meters
EMC EN 61326-1:2006
Temperature Coefficients Add 0.1 x specified accuracy for each
degree C above 28°C or below 18°C
Safety Specifications
Safety Compliance CAN/CSA-C22.2 No. 61010-1-04
ANSI/UL 61010-1:2004
ANSI/ISA-61010-1 (82.02.01):2004
EN/IEC 61010-1:2001 to
1000V Measurement Category (CAT) III
600V Measurement Category (CAT) IV
Pollution Degree 2
EN/IEC 61010-2-032:2002
EN/IEC 61010-031:2002+A1:2008
Agency Approvals
Batteries 2 AA, NEDA 15A, IEC LR6

Be ready for anything.

The Fluke 376 Clamp Meter offers improved performance perfect for a wide range of current measurement situations. With true-rms voltage and current measurements, the Fluke 376 can read up to 1000 V and 1000 A in both ac and dc modes.

Additionally, the Fluke 376 includes the new iFlex™ flexible current probe, which expands the measurement range to 2500 A ac while providing increased display flexibility, ability to measure around awkward sized conductors and improved wire access. The Fluke 376 is the direct replacement for the Fluke 337 Clamp Meter.

Features and benefits

  • iFlex flexible current probe expands the measurement range to 2500 A ac
  • CAT IV 600 V, CAT III 1000 V
  • True-rms ac voltage and current for accurate measurements on non-linear signals
  • Min, max, average and inrush recording to capture variations automatically
  • Integrated low pass filter and state of the art signal processing allows for use in noisy electrical environments while providing stable readings
  • Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
  • Ergonomic design fits in your hand and can be used while wearing protective equipment
  • Large, easy to read backlight display automatically sets the correct measurement range so you do not need to change the switch positions while taking a measurement
  • Three-year warranty
  • Soft carrying case

AC Current via Jaw
Range 999.9 A
Resolution 0.1 A
Accuracy 2% ± 5 digits (10-100 Hz)
2.5% ± 5 digits (100-500 Hz)
Crest Factor (50/60 Hz) 3 @ 500 A (375 and 376 only)
2.5 @ 600 A
1.42 @1000 A (376 only)
Add 2% for C.F. > 2
AC Current via Flexible Current Probe
Range 2500 A
Resolution 0.1 A (≤ 999.9 A)
1 A (≤ 2500 A)
Accuracy 3% ±5 digits (5 – 500 Hz)
Crest Factor (50/60Hz) 3.0 at 1100 A (375 and 376 only)
2.5 at 1400 A
1.42 at 2500 A
Add 2% for C.F. > 2
Distance from Optimum i2500-10 Flex i2500-18 Flex Error
Flexible current probe A 0.5 in (12.7 mm) 1.4 in (35.6 mm) ± 0.5%
B 0.8 in (20.3 mm) 2.0 in (50.8 mm) ± 1.0%
C 1.4 in (35.6 mm) 2.5 in (63.5 mm) ± 2.0%
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
DC Current
Range 999.9 A
Resolution 0.1 A
Accuracy 2% ± 5 digits
AC Voltage
Range 1000 V
Resolution 0.1 V (≤ 600.0 V)
1 V (≤ 1000 V)
Accuracy 1.5% ± 5 digits (20 – 500 Hz)
DC Voltage
Range 1000 V
Resolution 0.1 V (≤ 600.0 V)
1 V (≤ 1000 V)
Accuracy 1% ± 5 digits
mV dc
Range 500.0 mV
Resolution 0.1 mV
Accuracy 1% ± 5 digits
Frequency via Jaw
Range 5.0 – 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ± 5 digits
Trigger Level 5 – 10 Hz, ≥10 A
10 – 100 Hz, ≥5 A
100 – 500 Hz, ≥10 A
Frequency via Flexible Current Probe
Range 5.0 – 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ± 5 digits
Trigger Level 5 – 20 Hz, ≥ 25 A
20 – 100 Hz, ≥ 20 A
100 – 500 Hz, ≥ 25 A
Resistance
Range 60 kΩ
Resolution 0.1 Ω (≤ 600 Ω)
1 Ω (≤ 6000 Ω)
10 Ω (≤ 60 kΩ)
Accuracy 1% ± 5 digits
Capacitance
Range 1000 μF
Resolution 0.1 μF (≤ 100 μF)
1 μ F (≤ 1000 μF)
Accuracy 1% ± 4 digits
Mechanical Specifications
Size (L x W x H) 246 mm x 83 m x 43 mm
Weight 388 g
Jaw Opening 34 mm
Flexible Current Probe Diameter 7.5 mm
Flexible Current Probe Cable Length
(head to electronics connector)
1.8 m
Environmental Specifications
Operating Temperature 10°C – +50°C
Storage Temp -40°C – +60°C
Operating Humidity Non condensing (< 10 –°C)
≤ 90% RH (at 10°C – 30°C)
≤ 75% RH (at 30°C – 40°C)
≤ 45% RH (at 40°C – 50°C)
Operating Altitude 3000 meters
Storage Altitude 12,000 meters
EMC EN 61326-1:2006
Temperature Coefficients Add 0.1 x specified accuracy for each
degree C above 28°C or below 18°C
Safety Specifications
Safety Compliance CAN/CSA-C22.2 No. 61010-1-04
ANSI/UL 61010-1:2004
ANSI/ISA-61010-1 (82.02.01):2004
EN/IEC 61010-1:2001 to
1000V Measurement Category (CAT) III
600V Measurement Category (CAT) IV
Pollution Degree 2
EN/IEC 61010-2-032:2002
EN/IEC 61010-031:2002+A1:2008
Agency Approvals
Batteries 2 AA, NEDA 15A, IEC LR6

This clamp on meter is a combination power analyzer, power quality logger, and clamp meter, and is ideal for monitoring electronic loads.

The Fluke 345 is more than an electric power meter. Combining the functions of a clamp meter, oscilloscope, data logger and digital power meter into one handy device, the Fluke 345 is ideal for working with variable frequency motor drives, high efficiency lighting and other loads using switching electronics.

One of the leading wattage meters of the world, the multi-faceted Fluke 345 is packed with features such as a bright, color display to analyze the harmonic spectrum, a low-pass filter to remove high frequency noise and a high EMC immunity design, making the Fluke 345 power analyzer ideal for troubleshooting power quality on switching loads. The internal memory of this electric power meter enables long-term power quality logging for analysis of trends or intermittent problems. Additionally, the Hall Effect clamp meter design makes measurement of dc current possible without the need to break the circuit.

  • AC/DC current: Clamp-on measurement of ac current up to 1400 A rms and dc current up to 2000 A without breaking the circuit
  • Highest safety rating: 600 V CAT IV power analyzer is rated for use at the service entrance
  • Accurate in noisy environments: Clamp meter performs even with distorted waveforms present on electronic loads with low-pass filter
  • Data logging: Identify intermittent faults by logging any power quality parameter for minutes, or over a month, including harmonics
  • Verify batteries: Direct measurement of dc ripple (%) for battery and dc systems
  • Troubleshoot harmonics: Analyze and log harmonics digitally or graphically
  • Inrush current: Capture and analyze nuisance tripping, from 3 seconds to 300 seconds
  • Easy to use: Easily confirm power meter setup with large backlit color display of waveforms and trends
  • 3-Phase power: Built in capability for balanced loads
  • View graphs and generate reports: Use power analyzer with included Power Log software

Color transmissive LCD 320 x 240 pixels (70 mm diagonal) with 2 level backlight
Power supply
 Battery type 1.5 V Alkaline AA MN 1500 or IEC LR6 x 6
Battery life typically
 > 10 hours (backlight on full)
 > 12 hours (backlight reduced)
Battery Eliminator BE345
Input  110/230 V 50/60 Hz
Output  15 V dc, 300 mA
Ambient conditions (For indoor use only)
Reference conditions
 All accuracies stated at 23˚C ± 1˚C (73.4 °F ± 1.8 °F)
Operating temperature
 0 °C to 50 °C (32 °F to 122 °F)
Temperature coefficient of current
 ≤ ± 0.15 % of rdg per °C
Temperature coefficient of voltage
 ≤ ± 0.15 % of rdg per °C
Maximum relative humidity
 80 % for temperatures up to 31 °C (87 °F) decreasing linearly to 50 % relative humidity at 40 °C (104 °F)
Maximum operating altitude
 2000 m
Electrical safety
Maximum safe working voltages
 Safety IEC 61010-1 600 V CAT IV double or reinforced insulation, pollution degree 2
 Protection IP40; EN60529
Current measurement
 600 V ac rms or dc between uninsulated conductor and ground
Voltage measurement
 600 V ac rms or dc between either input terminal and ground, or 825 V between energized phase voltages (delta power config.)
EMC
Emission
 IEC/EN 61326-1:1997 class A
Immunity
 IEC/EN 61326-1:1997 Annex C Performance Criterion B
Mechanical
Dimensions (length x width x depth)
 300 mm x 98 mm x 52 mm (12 in x 3.75 in x 2 in)
Weight including batteries
 820 g/1.8 lb
Jaw opening
 60 mm
Jaw capacity
 58 mm diameter
Cleaning
 The unit can be cleaned with an Isopropanol impregnated cloth. Do not use abrasives or other solvents.
Electrical data
All accuracies stated at 23 °C ± 1 °C (73.4 °F ± 1.8 °F). See Ambient conditions specifications for temperature coefficients.
Current measurement (dc, dc rms, ac rms)
Measuring range
 0 to 2000 A dc or 1400 ac rms
Autorange facility
 40 A / 400 A / 2000 A
Resolution
 10 mA in 40 A range
 100 mA in 400 A range
 1 A in 2000 A range
Accuracy: DC and dc rms
I > 10 A:  ± 1.5 % rdg ± 5 digits
I < 10 A:  ± 0.2 A
Accuracy: AVG
I > 10 A:  ± 3 % rdg ± 5 digits
I < 10 A:  ± 0.5 A
Accuracy: Pk
I > 10 A:  ± 5 % rdg ± 5 digits
I < 10 A:  ± 0.5 A
Accuracy: AHr
I > 10 A:  ± 2 % rdg ± 5 digits
I < 10 A:  ± 0.5 AHr
Accuracy: CF (Crest Factor)
1.1 ≤ CF < 3:  ± 3 % rdg ± 5 digits
3 ≤ CF < 5:  ± 5 % rdg ± 5 digits
Resolution:  0.01
Accuracy: RPL (Ripple)
2 % ≤ RPL < 100 %:  ± 3 % rdg ± 5 digits
100 % ≤ RPL < 600 %:  ± 5 % rdg ± 5 digits
Resolution:  0.1 %
Idc > 5 A, Iac > 2 A
All measurements dc and 15 Hz to 1 kHz
Maximum overload 10,000 A or rms x frequency < 400,000
Amps rms is a true-rms measurement (ac + dc)

Versatile and rugged tools for applications with high currentsConfidently take reliable readings with the True-rms, Fluke 355 and 353 digital clamp meters; the tools of choice for high current clamp-on amp meter measurement up to 2000 A. The extra-wide jaw easily clamps around large conductors, typically found in high-current applications. The extra rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements.

Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads. The 355 also measures voltage and resistance, making this an ideal clamp meter for utilities, electrical contractors and industrial service technicians.

  • Reliably handle a wide range of high-current applications with 2000 A ac + dc true-rms, 1400 A ac, and 2000 A dc
  • The large 58 mm (2.3 in) jaw capacity is suitable for large or multiple conductors
  • CAT IV 600 V, CAT III 1000 V rating for added user protection
  • In-rush current measurement captures ‘power-on’ surge current with accuracy and repeatability
  • High voltage measurement of 1000 V ac + dc true-rms, 600 V ac, and 1000 V dc allows the user to perform multiple tests with only one tool (355 only)
  • Resistance to 400K ohms coupled with a continuity beeper provide the convenience of a multimeter in a clamp meter. (355 only)
  • Accurately measure frequency up to 1 kHz for optimum troubleshooting
  • Quickly analyze readings using the MIN, MAX, and AVG functions
  • A large backlit display allows for easy visibility in low-lit areas
  • Use the display hold feature to capture readings even when the display cannot be viewed
  • Use the low-pass filter to smooth out noisy loads and stabilize readings

Current measurement dc and ac 10 Hz to 100 Hz
Range : 40 A  Resolution: 10 mA
Accuracy, A: 1.5 % rdg + 15 digits
Trigger Level for Inrush: 0.50 A
Trigger Level for Hz Filter OFF: 2.50 A
Trigger Level for Hz Filter ON: 0.50 A
Range : 400 A  Resolution: 100 mA
Accuracy, A: 1.5 % rdg + 5 digits
Trigger Level for Inrush: 5.0 A
Trigger Level for Hz Filter OFF: 2.5 A
Trigger Level for Hz Filter ON: 2.5 A
Range : 2000 A; 1400 ac rms  Resolution: 1 A
Accuracy, A: 1.5 % rdg + 5 digits
Trigger Level for Inrush: 5 A
Trigger Level for Hz Filter OFF: 8 A
Trigger Level for Hz Filter ON: 8 A
Crest Factor (50/60 Hz)
Range : 40 A  Crest Factor* : 2 @ 33 A, 2.4 @ 27 A
Range : 400 A  Crest Factor* : 2 @ 330 A, 2.4 @ 270 A
Range : 2000 A; 1400 ac rms  Crest Factor* : 2 @ 1000 A, 2.4 @ 833 A
Current measurement ac 100.1 Hz to 1 kHz
Range : 40 A  Resolution: 10 mA
Accuracy > 10 A : 3.5 % rdg + 15 digits
Trigger Level for Inrush: 0.50 A
Trigger Level for Hz Filter OFF : 2.50 A
Trigger Level for Hz Filter ON : 0.50 A
Range : 400 A  Resolution: 100 mA
Accuracy > 10 A : 3.5 % rdg + 5 digits
Trigger Level for Inrush: 5.0 A
Trigger Level for Hz Filter OFF : 2.5 A
Trigger Level for Hz Filter ON : 2.5 A
Range : 2000 A; 1400 ac rms  Resolution: 1 A
Accuracy > 10 A : 3.5 % rdg + 5 digits
Trigger Level for Inrush: 5 A
Trigger Level for Hz Filter OFF : 8 A
Trigger Level for Hz Filter ON : 8 A
Voltage measurement (355 only) dc and ac 10 Hz to 100 Hz
(600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.)
Range : 4 V  Resolution: 1 mV
Accuracy: 1 % rdg + 10 digits
Trigger Level for Hz Filter OFF: 0.050 V
Trigger Level for Hz Filter ON: 0.050 V
Range : 40 V  Resolution: 10 mV
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 0.25 V
Trigger Level for Hz Filter ON: 0.25 V
Range : 400 V  Resolution: 100 mV
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Range : 600 V ac rms  Resolution: 1 V
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Range : 1000 V dc  Resolution: 1 V
Accuracy: 1 % rdg + 5 digits
Voltage measurement (355 only) ac 100.1 Hz to 1 kHz
(600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.)
Range: 4 V  Resolution: 1 mV
Accuracy: 3 % rdg + 10 digits
Trigger Level for Hz Filter OFF: 0.050 V
Trigger Level for Hz Filter ON: 0.050 V
Range: 40 V  Resolution: 10 mV
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 0.25 V
Trigger Level for Hz Filter ON: 0.25 V
Range: 400 V  Resolution: 100 mV
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Range: 600 V ac rms  Resolution: 1 V
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Ohms measurement (355 only)
Range: 400 Ω  Resolution: 0.1 Ω
Accuracy: 1.5 % + 5 digits
Range: 4 kΩ  Resolution: 1 Ω
Accuracy: 1.5 % + 5 digits
Range: 40 kΩ  Resolution: 10 Ω
Accuracy: 1.5 % + 5 digits
Range: 400 kΩ  Resolution: 100 Ω
Accuracy: 1.5 % + 5 digits
Continuity beeper (355 only)
 On at ≤ 30 Ω
 Off at ≥ 100 Ω
Frequency measurement
Measurement range  5.0 Hz to 1 kHz
Resolution  0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz)
Accuracy – 5.0 Hz to 100 Hz  0.2 % + 2 counts
Accuracy – 100.1 Hz to 1 kHz  0.5 % + 5 counts
Trigger level  Refer to current and voltage tables

*Add 2 % to error spec for CF > 2

General specifications
Batteries
 Six 1.5 V AA NEDA 15 A or IEC LR6
Battery life (with typical usage, backlight off)
 100 hours
Test leads
 Rated to 1000 V
Weight
 .814 kg (1.8 lb)
Jaw size
 58 mm (2.28 in)
Dimensions (LxWxD)
 300 mm x 98 mm x 52 mm (12 in x 3.75 in x 2 in)
Safety rating
 IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III
Environmental specifications
Operating temperature
 32 °F to + 122 °F (0 °C to +50 °C)
Storage temperature
 -4 °F to 140 °F (-20 °C to +60 °C)
Operating humidity
 0 to 95 % (non-condensing)
Operating altitude
 2000 m
Storage altitude
 10,000 m
IP rating
 42 (indoor use only)
Drop test requirements
 1 m
EMI, RFI, EMC
 FCC part 15, IEC/EN 61326-1:1997 class B, IEC/EN 61326:1997 3V/m, performance criteria B, EN61325
Temperature coefficients
Current:  0.1 % of reading per °C outside 22 °C to 24 °C
Voltage:  0.1 % of reading per °C outside 22 °C to 24 °C

The Fluke 360 leakage tester is a rugged and accurate solution for leakage current measurement.

Ideally designed for non-invasive checks of insulation condition, the Fluke 360 leakage meter allows you to perform tests without powering down the installation or disconnecting equipment – saving you time, without compromising on quality or safety.

The unique jaw design of the Fluke 360 AC Leakage Current Clamp Meter eliminates the influence of adjacent current conductors, and minimizes the effects of external magnetic fields, even at low currents. This allows you to perform accurate and reliable tests in today’s crowded electrical environments. The tough and high-quality jaw design of the Fluke 360 leakage tester guarantees high stability for long-term repeatability and durability.

  • Measurement of leakage current with 3 mA range and 1 µA of resolution, for accurate monitoring of insulation erosion
  • Broad range of measurement, from 1 µA up to 60 A, for all installation needs
  • Advanced shielding to ensure accurate results when measuring near other conductors
  • The high durability clamp construction can withstand over 50,000 operations, added ruggedness that extends the life of your leakage clamp.
  • Easy-to-carry, pocket-sized leakage current tester with wide 40 mm (1.5 in) jaw size
  • Handy “Display-Hold” button for capturing leakage current readings in hard-to-reach places
  • Auto power-off, with warning buzzer, saves battery life
  • Conformance to IEC1010 and EMC standard for confident measurements
  • Meets all of the applications and performance classes in safety standard VDE0404-4 and VDE0702 for leakage current and differential current measurement of electrical appliances

Method of detection
 Mean value
Display
Digital display:  3200 counts
Bar-graph display:  32 segments, LCD
Measurement Cycle
 2 times/second (Digital display), 12 times/second (Bar-graph display)
Range switching
 Auto-range
Ambient temperature and humidity
 0 °C to 50 °C, 80 % RH or less (no condensation)
Temperature coefficient
 0.05% of range/°C or less (within the ranges of 0 °C to 18 °C and 28 °C to 50 °C for measurement of 0-50 A)
Influence of external magnetic field
 0.0005% typical
Influence of conductor position
 Within accuracy
Circuit voltage
 <300 Vrms
Safety standard
 EN 61010-1, EN 61010-2-032, 300 V CAT III, Pollution Degree 2
Withstanding voltage
 3.7 kV ac
Battery type
 1 x 3 V Lithium battery (button cell) CR2032
Battery life
 Approx. 90 hours (when continuously used)
Auto power-off
 Approx. 10 minutes
Diameter of measurable conductor
 40 mm max.
Weight
 200 g
Dimension
 176 mm x 70 mm x 25 mm
Operating altitude
 2000 m
Electrical Specification
Specifications at
 23 ± 5 ºC, 80 % RH max
Accuracy
 (% readout + value of least significant digit)
3 mA
 Resolution: 0.001 mA
Accuracy: 1% + 5
Max Permissible current: 60 A rms
30 mA
 Resolution: 0.01 mA
Accuracy: 1% + 5
Max Permissible current: 60 A rms
30 A
 Resolution: 0.01 A
Accuracy: 1% + 5
Max Permissible current: 60 A rms
60 A
 Resolution: 0.1 A
Accuracy: 5% + 5
Max Permissible current: 60 A rms
Mean value detection and rms-value calibration
Accuracy specified at:  50/60 Hz

Be ready for anything.

The Fluke 365 is a rugged meter perfect for jobs where access to wires is difficult. The 365’s thin, small jaw is detachable with a flexible lead, which makes gaining access to wires and viewing the display easier than ever.

Features and benefits

  • 200 A ac and dc current measurement with detachable jaw
  • 600 V ac and dc voltage measurement
  • Detachable jaw makes accessing wires and viewing the display easier
  • Built in flashlight/torch allows for easy illumination and identification of wires
  • CAT III 600 V
  • Compact design fits in your hand and can be used while wearing protective equipment
  • State of the art signal processing allows for use in noisy electrical environments while providing stable readings
  • Large, easy to read, backlight display automatically sets the correct measurement range so you do not need to change switch positions while taking a measurement
  • Three-year warranty
  • Soft carrying case

Diameter of measurable conductor 0.71″ or 18 mm max
Operating temperature -14 to 122ºF (-10 to 50ºC)
Storage Temperature -40 to 140ºF (-40 to 60ºC)
Operating Humidity < 90% @ 10 to 30 ºC, < 75% @ 30 to 40ºC
Operating Altitude 0 to 2000 m
Size 225 x 65 x 46 mm, (8.858 x 2.559 x 1.811 in.)
Weight 275g, (10 oz.)
Temperature Coefficient 0.01% ºC
(<18ºC or > 28ºC)
Warranty Three years

Reduce downtime – Find leakage currents without taking equipment offline

The Fluke 369 true-rms leakage current clamp meter helps users detect, document, record and compare leakage current readings over time as a means of preventing unplanned downtime, and identifying intermittent GFCI and RCD trips, all without taking equipment off line.

The Fluke 369 has an oversize 61 mm jaw for work with extra-large conductors. The clamp’s jaw is fully shielded to accurately capture very small leakage signals, and to minimize external electromagnetic interference.

overview

  • True-rms measurements for accuracy when measuring complex, non-sinusoidal waveforms
  • 61 mm jaw opening
  • Highest resolution of 1 μA, measure up to 60 A
  • Selectable filter function removes unwanted noise
  • Max/Min/Average readings and hold function
  • Forward-facing LED worklight for use in dark wiring cabinets
  • Backlit display; auto backlight off and auto power off for extended battery life
  • CAT III 600V safety rating

Measurement function Alternating current
AC ampere range 3 mA, 30 mA, 300 mA, 3 A, 30 A, 60 A
Range selection mA / A: manual selection
3 mA / 30 mA / 300 mA: automatic selection
3 A / 30 A / 60 A: automatic selection
Range / Resolution 3 mA¹ / 0.001 mA
30 mA / 0.01 mA
300 mA / 0.1 mA
3 A / 0.001 A
30 A / 0.01 A
60 A / 0.1 A
Accuracy – filter activated (40 to 70 Hz), filter off (40 to 1 kHz)² 3 mA – 30 A
60 A
1% + 5 digits
2% + 5 digits
Frequency 40 Hz to 1 kHz
Crest Factor 3
After calibration accuracy is valid for one year. Accuracy is expressed as ± (% of reading + digits). Reference conditions 23 ±5 °C and a maximum relative humidity of 80%.
¹The minimum value is 10 μA rms.
²Outside of the TC / °C 18 °C to 28 °C, 0.02 + 1
Physical
Display (LCD) Digital readout: 3300 count
Display refresh rate 4 times / sec
Maximum conductor diameter 61 mm
Dimensions 257 x 116 x 46 mm
Weight 600 g
Battery 2 AA, IEC LR6, NEDA 15A, alkaline
Battery life Expected battery life, without using backlight and spotlight, is more than 150 hours
Automatic shut-down Meter automatically shuts down after 15 minutes of inactivity
Safety and Environmental Specifications
General safety IEC 61010-1: Pollution Degree 2
Measurement safety IEC 61010-2-032: CAT III 600 V / CAT IV 300 V
Operating temperature -10 °C to +50 °C
Storage temperature -40 °C to +60 °C
Operating humidity Non-condensing (<10 °C)
90% relative humidity (10 °C to 30 °C)
75% relative humidity (30 °C to 40 °C)
45% relative humidity (40 °C to 50 °C)
Protection class IEC 60529: IP30 (jaw closed)
Operating altitude 2000 m
Storage altitude 12000 m
Current sensor action category IEC 61557-13: Class 2, ≤30 A / m
Electromagnetic compatibility (EMC)
International
IEC 61326-1 Industrial Electromagnetic Environment
CISPR 11 Group 1 Class B
Group 1 Generated inside the equipment and / or use radio frequency energy associated with conducting the energy for the device’s own internal functions is essential.
Class B Equipment for home appliances and residential buildings directly connected to a low voltage power supply network equipment. When this device is connected to a test object, it may exceed the emission levels produced by CISPR 11 requirements.
Korea (KCC): Class A Equipment (Industrial Broadcasting & Communication Equipment)
Class A This product meets the requirements of industrial electromagnetic equipment, vendors or users should be aware of this. This device is intended for use in a commercial environment, instead of the home environment.
USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.